R-Value to U-Factor Calculator (R-Value, RSI & U-Factor Converter)

Enter an R-value, RSI or U-factor and get all four forms at once, or pick an insulation material and a thickness to see what that layer works out to. Everything runs in your browser.

1. Convert R-value, RSI or U-factor

2. R-value and U-factor of an insulation layer

R = thickness × R per inch. The R per inch fills in a starting value when you choose a material; replace it with the labelled value of your product.

Quick chart: common R-values

R-value (IP)RSI
m²·K/W
U-factor (IP)
BTU/h·ft²·°F
U-value (SI)
W/m²·K
R-132.290.07690.437
R-193.350.05260.299
R-305.280.03330.189
R-386.690.02630.149

Unit conversions only, rounded for reading; not product ratings or code minimums. Longer charts are in the guide's reference tables. To add up several layers in series, use the R-value converter with layer totals.

Formulas and sources

U = 1 ÷ R  (in matching units)
RSI = R(imperial) × 0.1761101838
U(W/m²·K) = U(BTU/h·ft²·°F) × 5.678263
R(layer) = thickness (in) × R per inch

Frequently asked questions

How do I convert R-value to U-factor?

Take the reciprocal: U = 1 ÷ R in matching units. An R-13 wall has an imperial U-factor of 1 ÷ 13 ≈ 0.0769 BTU/h·ft²·°F. For a metric U-value in W/m²·K, divide 5.678 by the imperial R-value: 5.678 ÷ 13 ≈ 0.437.

How do I convert R-value to RSI?

Multiply the imperial R-value by 0.176110 (or divide by 5.678263). R-19 is about RSI 3.35 m²·K/W.

How do I find the R-value of an insulation layer from its thickness?

Multiply the thickness in inches by the material's R-value per inch. For example, 3.5 in of open-cell spray foam at R-3.6 per inch gives about R-12.6. Use the labelled value for the product you are considering.

Are U-factor and U-value the same?

They describe the same property, thermal transmittance. In North America U-factor usually means imperial units (BTU/h·ft²·°F), while U-value usually means metric (W/m²·K). 1 BTU/h·ft²·°F equals 5.678 W/m²·K.

Does this calculator tell me if my wall meets code?

No. It converts numbers you enter. It does not measure any product and does not check an assembly against an energy code; consult your local code authority for requirements.

Limits

Background and worked examples: U-value and R-value: how to convert U-factor to R-value (and RSI).